Ningbo Joiwo Explosion-proof Science and Technology Co., Ltd.

2025-07-11

How to Choose the Best Explosionproof Telephone Wall Mounted HandsFree Emergency Intercom for Pharmaceutical Labs

Table of Contents

How to Choose the Best Explosionproof Telephone Wall Mounted HandsFree Emergency Intercom for Pharmaceutical Labs

Safety always comes first when choosing equipment for pharmaceutical labs. An Explosionproof telephone Wall Mounted HandsFree Emergency Intercom protects people and property in hazardous environments. Users need an IP Explosion Proof Telephone that meets strict hygiene rules. Many labs trust an emergency Explosion Proof Telephone with ATEX Explosion Proof Telephone certification.

Explosionproof telephone Wall Mounted HandsFree Emergency Intercom: Safety and Compliance

Explosionproof telephone Wall Mounted HandsFree Emergency Intercom: Safety and Compliance

ATEX and IECEx Certifications

When choosing an Explosionproof telephone Wall Mounted HandsFree Emergency Intercom for a pharmaceutical lab, safety certifications matter most. ATEX and IECEx are two major certifications that help users know if a device is safe for explosive environments. ATEX is a legal requirement in the European Union, while IECEx is an international standard. Both certifications show that the equipment can handle hazardous atmospheres, but they have some differences.

Here’s a quick comparison:

Aspect ATEX Certification IECEx Certification
Scope Mandatory EU directive for equipment in explosive atmospheres Voluntary international certification system for equipment in explosive atmospheres
Legal Status Legally required within the European Union Voluntary, internationally recognized but not legally mandatory in the EU
Certification Process Rigorous product assessment, design evaluation, and regular manufacturing audits Unit verification for each product, testing by accredited labs, streamlined Quality Assessment Report
Markings ‘Ex’ symbol plus CE marking, group/category, gas/dust type, temperature code ‘Ex’ symbol plus service facility ID, protection concept, gas/dust group, temperature class
Geographic Recognition Mandatory and recognized within EU and EEA countries Recognized globally, facilitating international trade but not a legal substitute for ATEX in the EU
User Responsibilities Users must classify hazardous zones, select equipment with appropriate ATEX category and markings, and follow installation and maintenance instructions Users must verify IECEx certification, select equipment with appropriate Equipment Protection Level (EPL), and comply with manufacturer’s operational guidelines
Applicability to Pharmaceutical Environments Ensures explosionproof telephones meet strict EU safety standards for potentially explosive atmospheres in pharmaceutical settings Provides internationally accepted certification for explosionproof telephones, facilitating global market access and compliance
Market Strategy Mandatory for EU market access; often combined with IECEx for broader acceptance Preferred for international markets; often sought alongside ATEX to expand marketability

Pharmaceutical labs in the EU must use ATEX-certified equipment. Labs outside the EU often look for IECEx certification to meet global standards. Many manufacturers, like JOIWO, offer both certifications to cover all needs.

IP Ratings and Environmental Protection

Pharmaceutical labs face dust, moisture, and chemical splashes every day. An Explosionproof telephone Wall Mounted HandsFree Emergency Intercom must keep working in these tough conditions. That’s where IP ratings come in. IP66 and IP67 are common ratings for explosionproof telephones. These ratings mean the device is dust-tight and can handle strong water jets or even brief submersion.

For example, an IP66 rating ensures the intercom blocks all dust and resists powerful water sprays. This keeps the inside parts safe and working, even if the lab gets messy. The enclosure also needs to prevent dust from entering and causing explosions. Markings like ‘Ex’ and ‘tb’ show that the device meets explosion-proof and dust ignition protection standards.

Tip: Always check the IP rating before buying. A higher IP rating means better protection against dust and water, which is crucial for pharmaceutical labs.

Manufacturers design these intercoms to meet strict standards worldwide. In Europe, ATEX and IECEx set the bar. In the US and Canada, NEC and CSA standards apply. Most top brands, including JOIWO, use stainless steel or heavy-duty metal cases to boost durability and protection.

Chemical Resistance and Hygiene Standards

Pharmaceutical labs require strict hygiene. Equipment must resist harsh cleaning agents and not harbor bacteria. An Explosionproof telephone Wall Mounted HandsFree Emergency Intercom with a stainless steel enclosure, like the JOIWO JWBT813, stands up to frequent cleaning and disinfection. Stainless steel resists corrosion and prevents microorganisms from sticking to the surface.

Many manufacturers use materials like SUS304 stainless steel or aluminum alloy. These materials handle strong chemicals and daily cleaning. The smooth surfaces make it easy to wipe down the intercom, keeping the lab sterile. This is especially important in clean rooms, where even a small amount of contamination can cause problems.

  • Stainless steel enclosures resist rust and chemical damage.
  • Smooth surfaces help prevent bacteria buildup.
  • Devices meet hygiene standards for food, medical, and pharmaceutical industries.

Choosing an intercom with these features helps labs stay safe, clean, and compliant with industry rules.

Functional Features of Explosionproof telephone Wall Mounted HandsFree Emergency Intercom

Functional Features of Explosionproof telephone Wall Mounted HandsFree Emergency Intercom

HandsFree Operation and Usability

Handsfree operation changes the way lab personnel communicate during emergencies. With this feature, users do not need to touch the device, which helps keep the environment sterile. Many pharmaceutical labs prefer handsfree systems because they reduce contamination risk and let staff focus on their tasks.
Some key advantages include:

  • Lower contamination risk, which is vital for hygiene.
  • Free hands for other important work, especially in hazardous or clean areas.
  • Fast and clear communication, which improves emergency response.
  • Scalable communication, connecting multiple labs or control centers.
  • High clarity and non-blocking calls, even in urgent situations.

The JOIWO JWBT813, for example, uses a stainless steel housing and a vandal-resistant keypad, making it both durable and easy to use in critical environments.

Audio Clarity and Emergency Call Functions

Clear audio is essential in noisy labs. The best intercoms use advanced audio controls to keep voices clear, no matter the background noise.
Here’s a quick look at recommended audio features:

Feature / Standard Description
Distortion-Free Automatic Level Control Keeps audio clear from whispers to shouts, adjusting to noise levels.
User-Adjustable Controls Lets users change audio settings for different rooms.
Microphone Options Offers choices for different lab setups.
Headsets and Speakers Supports private or group communication.
Compliance with UL 1069 Meets emergency call system standards.
Hands-Free Communication Allows use without physical contact, supporting hygiene.
Audio Control in Challenging Environments Maintains intelligibility despite loud backgrounds.

Emergency call functions often include a single-push SOS button, LED indicators, and a vandal-resistant keypad. These features help staff act quickly and confidently.

Wall-Mounting and Space Efficiency

Space matters in a busy lab. A wall-mounted design saves valuable workspace and keeps the device within easy reach. The Explosionproof telephone Wall Mounted HandsFree Emergency Intercom installs securely on any wall, making it ideal for tight or high-traffic areas.
Stainless steel construction and compact design mean the intercom fits well in both small and large labs. This setup also keeps cables and controls out of the way, reducing clutter and improving safety.

Durability and Maintenance Considerations

Durability and Maintenance Considerations

Material Quality and Corrosion Resistance

Material choice plays a big role in how long an explosionproof telephone lasts in a pharmaceutical lab. Stainless steel stands out for its strength and ability to resist corrosion. This makes it a top pick for labs that use strong cleaning agents or work with harsh chemicals. The JOIWO JWBT813, for example, uses SUS304 stainless steel. This material keeps the device safe from rust and damage, even in tough environments.

Other materials also offer unique benefits:

  • Aluminum is light and helps move heat away from the device. It resists corrosion and chemical exposure, which helps the phone last longer.
  • Cast iron gives strong impact resistance. It protects the inside parts if something hits the phone.
  • Non-metallic materials like fiberglass reinforced polyester (FRP) and polycarbonate resist corrosion and provide electrical insulation. Polycarbonate also stands up well to impacts and heat.
  • Sealing materials such as silicone and neoprene keep out dust, moisture, and gases. This helps the phone stay explosion-proof and reliable.

Choosing the right material means the intercom can handle daily wear and tear, chemical splashes, and even accidental bumps.

Ease of Cleaning and Disinfection

Pharmaceutical labs need equipment that is easy to clean. Smooth surfaces and simple designs help staff wipe down the intercom quickly. Stainless steel enclosures, like those on the JWBT813, do not trap dirt or bacteria. Staff can use strong disinfectants without worrying about damaging the device.

Tip: Look for intercoms with rounded edges and minimal seams. These features make cleaning faster and help keep the lab sterile.

Regular cleaning keeps the equipment safe and extends its life. When labs choose devices that resist chemicals and allow easy disinfection, they support both safety and efficiency every day.

Installation and System Integration

Installation and System Integration

Compatibility with Existing Communication Systems

Pharmaceutical labs often use different communication systems across their facilities. The best explosionproof intercoms work with many protocols, making integration easy. Most modern systems support:

This flexibility means labs can connect new intercoms to their current networks without major changes. These systems also meet IECEx certification, so they fit safely into hazardous environments. When labs choose intercoms that support multiple protocols, they make future upgrades and expansions much simpler.

Power Supply and Connectivity Options

Reliable power and strong connections keep emergency intercoms running when they are needed most. Labs can pick from several power supply options. The table below shows some of the most reliable choices:

Feature Details
Power Supply Options 24V DC input or Power over Ethernet (PoE)
Backup Power Duration Up to 85 minutes at 75W full load
Enclosure IP66 rated, 316L stainless steel, handles harsh, wet, or explosive areas
Operating Temperature -40°C to +70°C
Connection RJ45 Ethernet socket with IP67 plug connector

Wired systems often provide the most reliable and interference-free communication. They help labs meet strict standards like ISO 14644 and FDA cGMP. Wired intercoms also avoid radio frequency interference, which is important for safety and contamination control. Wireless options, such as Wi-Fi, offer flexibility but may need extra security and interference management.

Technical Support and Customization

Leading manufacturers understand that every pharmaceutical lab has unique needs. They offer strong technical support and a wide range of customization options, such as:

  • Support for analog, VoIP, and SIP protocols
  • Rugged construction with vandal-resistant parts
  • Full keypads with programmable speed dial buttons
  • Simple wall or pillar mounting
  • Compliance with ATEX, CE, FCC, RoHS, and IECEx certifications
  • Customization for color, keypad layout, and spare parts
  • Warranty periods from 18 months to 2 years

Customization helps labs meet local safety rules and operational needs. Modular designs also make it easier to adapt intercoms for special applications. With these options, labs can create a communication system that fits their workflow and keeps everyone safe.

Cost, Value, and Warranty

Initial Investment and Long-Term Reliability

Choosing an explosionproof telephone for a pharmaceutical lab means looking beyond the price tag. Many top brands, like Dorland, show that investing in high-quality, certified devices pays off over time. These phones often come with features such as ATEX and IECEx certifications, shock resistance, and waterproofing. They use corrosion-resistant materials and have IP67 or higher ratings. These features help the device last longer, even in tough environments.

Labs that pick rugged, reliable phones spend less on repairs and replacements. Maintenance costs drop because the equipment stands up to daily use, harsh cleaning, and accidental bumps. Over time, the total cost of ownership goes down. A strong support team and good warranty coverage also help keep downtime to a minimum. When labs balance upfront costs with long-term benefits, they get better value and peace of mind.

Tip: Investing in a durable, certified intercom reduces unexpected expenses and keeps lab operations running smoothly.

Warranty and Service Agreements

Warranty and service agreements add another layer of value. Many explosionproof telephones come with warranties ranging from 12 to 18 months. For example, some models offer an 18-month warranty, showing confidence in their durability. Others provide a standard one-year warranty against defects in materials and workmanship. Service agreements may also include a 30-day guarantee on repairs or maintenance work.

These warranties usually cover manufacturing defects but not consumables or damage from misuse. Labs should check the details before buying. A solid warranty and responsive service team help labs fix problems quickly and avoid long delays. This support is especially important in regulated industries like pharmaceuticals, where safety and uptime matter most.

Final Selection Checklist for Explosionproof telephone Wall Mounted HandsFree Emergency Intercom

Final Selection Checklist for Explosionproof telephone Wall Mounted HandsFree Emergency Intercom

Actionable Criteria Summary

Selecting the right Explosionproof telephone Wall Mounted HandsFree Emergency Intercom for a pharmaceutical lab takes careful planning. Labs need to make sure every device meets strict safety and operational standards. Here’s a practical checklist to help teams make the best choice:

  • Confirm the device holds ATEX, IECEx, or NEC certifications. These show the intercom is safe for hazardous lab environments.
  • Match the intercom’s hazardous area classification to the lab’s specific risk zone. This step helps prevent safety mismatches.
  • Choose models with intrinsically safe designs. These limit electrical and thermal energy, reducing the risk of ignition.
  • Look for enclosures made from high-strength stainless steel or non-sparking materials. These materials resist corrosion and prevent accidental sparks.
  • Make sure the intercom features a flameproof enclosure and intrinsic safety barriers. These add extra layers of protection.
  • Set up a regular inspection and maintenance schedule. Qualified personnel should handle these tasks to keep the device reliable.
  • Train all staff on proper use and handling of explosionproof telephones. Training builds confidence and reduces mistakes.
  • Keep detailed records of inspections, maintenance, and repairs. Good records support compliance and help with future planning.
  • Update firmware and software as soon as new versions become available. This keeps the system secure and functional.
  • Work with experts for custom design or integration. Every lab has unique needs, so professional advice can make a big difference.

Tip: Always select devices that have passed rigorous testing and meet or exceed all safety standards. This ensures the intercom will perform reliably when it matters most.


Safety and compliance always come first when choosing an explosionproof intercom. Readers should use the checklist to cover every important detail. They can find the best fit by balancing safety, features, durability, and value. Smart choices keep labs safe and operations running smoothly.

FAQ

What certifications should a pharmaceutical lab explosionproof intercom have?

Labs should look for ATEX, IECEx, and CE certifications. These prove the device meets strict safety standards for hazardous environments.

How often should staff clean the explosionproof intercom?

Staff should clean the intercom daily or after each use. Stainless steel surfaces make cleaning quick and help maintain hygiene.

Can the JOIWO JWBT813 connect to existing lab phone systems?

  • Yes, the JWBT813 supports analog connections.
  • It integrates easily with most standard lab communication systems.
Facebook
Twitter
Email
Print

newsletter

Copyright © 2025 All rights reserved. Powered by Deepvaluer.
en_USEnglish

Looking forward to your contact with us

Let's have a chat